Rewind devices on Copernico

This article explains how to rewind (recover) from Copernico the readings that timing devices have stored in the cloud, applying a time offset if needed, selecting several devices at once and choosing whether or not to apply the configured filters.

This procedure applies to timing devices connected to Copernico through the CLOUD V2 integration.

ℹ️ Note: rewinding is useful, for example, to recover readings after a connection loss, to re-import readings with a corrected time offset, or to repeat the import with and without filters.

 

 

1. Accessing the devices panel

In the event Dashboard, the CLOUD V2 widget shows the timing devices grouped by location, along with their status: number of readings, time of the last reading, battery, CPU and reader temperature, and active antennas.

To manage rewinds, click the Devices icon in the right-hand sidebar.

 

 

The CLOUD V2 panel opens. Here you can filter by event using the Event drop-down and see the devices connected at each location (for example, Meta, Salida 5K, 5K or 10K). At the bottom, the Time to next update bar shows the time remaining until the next update.

 

 

2. Opening the rewind window

Next to each timing device you will find the options menu (⋮). Click it to display two options:

  • Rewind: opens the rewind window on the Rewind V2 tab.
  • Use offset: opens the same window on the Offset tab.

 

 

3. Configuring the rewind

The rewind window is titled with the location name (for example, META) and contains all the rewind parameters.

 

 

 

3.1 Selecting one or several devices

The left-hand column lists the timing devices at the location. The device from which you opened the window is selected by default.

You can rewind several devices at once by ticking their checkboxes. The rewind will run with the same settings for all selected devices.

 

3.2 Time range and location

Field Description
From Start date and time of the reading interval to recover.
To End date and time of the reading interval to recover.
Location Copernico location to which the rewound readings will be assigned.

 

3.3 Rewind offset

Use Apply rewind offset to shift the time of the rewound readings:

  1. Select + to add time or - to subtract it.
  2. Enter the value in the time field using the hh:mm:ss.000 format (default 00:00:00.000, no offset).
✅ Recommendation: the offset can be applied to each timing device. If you need a different offset for each one, rewind them separately, selecting only the relevant device and its offset in each rewind.

 

3.4 Chip encoding

Use Chip encoding to select the encoding used to interpret the tags in the rewound readings. The default value is Inherit, which inherits the encoding already configured.

 

3.5 Applying filters

The Apply filters checkbox applies the filters set in the current export configuration to the rewind (Apply configured filters in the current export configuration).

  • Ticked: only readings that meet the configured filters are recovered.
  • Unticked: readings are recovered without applying the filters.
ℹ️ Note: if you use filters, you can run rewinds with and without filters simply by ticking or unticking this checkbox before each rewind.

 

4. Running the rewind

Once you have reviewed all the parameters, click the REWIND button in the bottom-right corner of the window.

⚠️ Important: check the From / To range, the Location and the offset before clicking REWIND, as the readings will be imported with these settings.

 

When the rewind finishes, the cloud-stored readings of the selected devices within the specified interval will be recovered in Copernico at the chosen location, with the offset and filters you configured.