TSConnector can send the readings of your timing devices to Wiclax in real time. The connection is configured in both applications: in TSConnector you choose the port and assign the devices to each timing point, and in Wiclax you create one acquisition per timing point.
Contents
1. Configure the export in TSConnector
- In TSConnector, open the menu (☰) in the top left corner, go to Exports and choose the Wiclax export. The Wiclax Connector screen opens.
- In the Settings tab, choose the port you will work with in Port. The computer's address is shown below, in Host.
- If needed, limit the readings that are sent with Sportmaniacs Filters and with the Detections Window (start date and time, Start, and end date and time, Finish).
- Click Save Settings.
The User Guide link, next to Port, opens a quick guide with the steps to configure Wiclax (the same as in section 3).
2. Assign devices to timing points
- Open the Mappings tab.
- Click Add Row and type the name of the timing point in Timing Point.
- In Devices, choose the device you will use at that timing point. To add another device to the same timing point, click the + button. If a device is not in the list, click Refresh Devices.
- Repeat steps 2 and 3 for each timing point. Use the X to remove a timing point or a device you will not use.
- When all the timing points and devices are set, click Save Mappings.
3. Configure Wiclax
These are the steps of the TSConnector quick guide (User Guide):
- In Wiclax, go to the Results - Classifications tab and click Acquisitions.
- Select Timingsense from the list in the ribbon. Add as many Acquisitions as you have timing points.
- In the far-right column, enter the HOST IP address and then the PORT number. If you need to change the port number, choose another one from the list in TSConnector and make the same change in Wiclax.
- In the Target column, under Source@, enter the APP Code of the matching timing point. Type the APP Code in CAPITAL LETTERS.
- In the Timing Points table, click Connect in the Reading column.
- Click Test next to each timing point in TSConnector: it sends dummy data to Wiclax to check that the connection is set up properly. If the data appears in Wiclax, the connection is correct.
- Click Connect in the Timing Points table to start receiving the readings in real time.
4. Monitor devices and rewind readings
The Devices tab shows all the devices assigned to a timing point. Each row shows:
- Status: whether the device is connected (ON) or not (OFF).
- Battery: the battery level and whether it is charging.
- Unique and Total: the unique readings and the total number of readings.
- Time lapse: the time since the last reading.
On the right, Latest Detections shows the readings as they arrive (TimingPoint, ChipID, ReadType and TimeStamp).
To send the readings of a device again:
- Click the rewind button (Rewind) in its row.
- Enter the start (From) and the end (To) of the period.
- If there are several timing points, select the ones the device's readings are exported to.
- Click Confirm.
5. Video transcript
In the video, the timing point and device sections are shown with the CSV export (CSV Export Connector); they work the same way in the Wiclax export.
In the Wiclax menu, we will select the port we want to work with, on the host. We have here a small guide on how we have to perform the entire configuration with the Wiclax menu, and we must follow all of these steps.
Once we know what type of export we want to perform, we will select the option, configure our choice and save the changes.
The first step to add timing points and devices will be to add the timing points in a list and select the devices we want to use at that timing point. Simply, we will add a line, give it a name, and we will add one or several devices that we are going to use at that point.
If we need to make more timing points, we'll simply add a new line and repeat the process. If we want to remove any, we can press the X to delete. In the same way, we can remove the devices that we have added and do not want to use.
After we have finalized all the timing points and all the devices we are going to use, we will save the mapping.
In this list, we will see all the devices that we have set up at any point. And on the right, we will be able to see the readings being generated by these devices. Each line will indicate a device, the status (whether it is connected or not), if the battery is charged and if it is charging, the unique readings, the total readings and the time that has passed since the last reading.
We will be able to rewind the range by marking a start and an end. And if there have been several configurations in this type of export, we will be able to see which timing points we are going to export the devices to. We will just need to confirm to finalize.
And we can save all the readings that have already passed to a different file than the one we configured, if necessary.
Comments